Features of the dose Badge Noise Dosimeters
| |
- No wires or controls on the badge to catch or knock
- Simultaneous, dual channel measurements:
- Channel 1, programmable exchange rate, time weighting,
criterion time and level
- Example: OSHA Q=5dB: Lavg, Dose %, TWA and Peak
- Channel 2
- Q=3dB (ISO): Leq, Dose %, Lep,d and Peak
- "A" frequency weighting with "C" weighting
for Peak
- Very rugged cast alloy case
- Powered by an internal rechargeable battery
- dose Badge and Reader communicate using an infra-red link
- Supplied with software to download measurements to a Windows
PC
- User programmable to either Q=3 (ISO) or Q=5 (OSHA)
- Time
History gives graph of noise levels
- Measures down to 70 dB(A)
- True Peak reading with Peak Time
History
- 115 dB(A) sound level exceeded flag
- Extra user-programmable settings for MSHA, AICHE and ACGIH
noise regulations
|
Noise Dosimeter Specifications
| |
Standards |
ANSI S1.25:1991 Personal Noise Dosimeters
IEC 61252:1993 Personal Sound Exposure Meters
Reader's Internal Acoustic Calibrator to IEC 60942:2001 Class 2
|
| |
Measurement Range |
70 dB(A) to 130
dB(A) RMS
120 dB(C) to 140 dB(C) Peak |
| |
Measurement Functions |
All configurations
dose Badge Settings, Calibration Record
Measurement Duration, Highest Peak (C) Sound Level
Overload Exceedence, Battery Status
115 dB(A) Maximum Sound Level Exceedence
1 Minute Time History of:
LAeq (3dB)
LAVG (4dB or 5dB)
Peak (C) Level
Battery Level |
| |
|
For 3dB Exchange Rate
LAeq, LEX,8h, LAE, % Dose, Exposure (Pa2h),
Estimated % Dose, Estimated Exposure (Pa2h) |
| |
|
For 4dB & 5dB Exchange Rates
LAVG, TWA, % Dose, Estimated % Dose
|
| |
Weightings |
‘A ’ for all RMS measurements. ‘C ’
for Peak Sound Pressure |
| |
doseBadge Configuration |
ISO (Q=3, Time=None) OSHA (Q=5, Time=Slow) |
| |
|
Exchange Rate (3dB, 4dB or 5dB) Criterion
Level (80dB, 85dB, 87dB, 90dB) Criterion
Time (8hrs, 12hrs, 16hrs, 18hrs) Threshold
(None, 80dB, 85dB, 90dB) Time Weighting
(None, ‘S ’ (Slow)) |
| |
Memory |
The Reader Unit can store the following measurement data:
With 8 hours of 1 minute Time History
Up to 93 measurements
With 12 hours of 1 minute Time History
Up to 64 measurements
With 24 hours of 1 minute Time History
Up to 33 measurements |
| |
Power |
doseBadge
NiMH Rechargeable Battery
Reader
2 x AA/LR6 with Auto Power Switch Off
CU Series Chargers
CU:195A Mains Power Supply with UK, EU
or US plug |
| |
Output |
doseBadge Infrared
to RC:110A Reader Unit Reader
USB 2.0 to computer |
| |
Dimensions |
Microphone Apex Ø13.0mm,Base Ø47mm,Height
38mm |
| |
Environmental |
Temperature -10 °C
to +50 °C Operating -20 °C to
+60 °C Storage Humidity
Up to 95%RH Non-Condensing |
| |
Weight |
dose Badge: 45gms (1.6oz)
Reader: 400gms (14oz) |
| |
Software |
dBLink and dBase Database supplied as standard.
Compatible with Microsoft Windows versions 98 or later |
|
|